What Rw is
ISO 717-1 defines single-number quantities for the airborne sound insulation of building elements such as walls, floors, doors and windows. Rw is the one used for laboratory results: it condenses a measurement taken across one-third-octave frequency bands into one figure in decibels. The measurement itself follows ISO 10140-2, a laboratory method for building products such as walls, doors, windows, façade elements and glazing, adopted in the Gulf as GSO ISO 10140-2:2025. The higher the Rw, the less airborne sound the element lets through.
ISO 717-1 also takes account of different noise spectra, such as noise inside a building and traffic outside, through spectrum adaptation terms, C and Ctr. A test report may give them next to the main figure, written as Rw (C; Ctr).
Laboratory Rw and the finished room
A laboratory test isolates the element. ISO 10140-2 is carried out in facilities where sound transmission through flanking paths is suppressed, and the standard states that its results are not directly applicable to the field without accounting for flanking transmission, boundary conditions and total loss factor. In a building, sound also finds its way around a partition: through gaps at its head and base, through penetrations for services, and through the door.
Field performance is measured with a different standard, ISO 16283-1, which sets procedures to determine the airborne sound insulation between two rooms in a building; its result is a field value, not a laboratory Rw. Building regulations keep the two apart. The Scottish Government's domestic technical handbook, for example, sets internal walls in homes at 40 dB Rw and relies on a laboratory test, because on-site tests cannot be relied upon: a door in the wall gives sound a path around it.
What moves the number
- The build-up. For glass partitions, Rw depends on the glass build-up and the junctions: single or double glazing, glass thickness and how panels meet. Line Systems Glass Acoustic, for example, takes 10, 12 or 16 mm glass, and Glass Slim has a Slim Double configuration for higher acoustic targets.
- Seals at the head and base. The WELL Building Standard (Feature 81, Sound barriers) asks for acoustically rated partitions to be sealed at the top and bottom tracks.
- Penetrations. The same standard asks for every penetration through the wall to be packed and sealed.
- The door. WELL asks for doors to conference rooms and private offices to have gaskets, sweeps or a non-hollow core, since an unsealed door gives sound a way around the wall.
- Workmanship. In gypsum walls, WELL also asks for board seams to be staggered.
Setting a target for a meeting room
There is no single Rw that fits every meeting room. The number belongs in the project's acoustic brief, set by the designer or an acoustic consultant against the standard or regulation that applies to the project. What a supplier should give you is evidence that a tested build-up meets it. A workable sequence:
- State the target with its metric: a laboratory Rw for the partition, or a field value for the finished room.
- Choose a build-up whose laboratory report meets the partition target.
- Detail the head, base, junctions, door and penetrations so the room does not lose that performance on site.
- If the brief sets a field value, plan the site test to ISO 16283-1 before handover.
How to read and request a test report
A figure without a report is a claim. A usable acoustic report states:
- the laboratory and the report number
- the test date
- the test standard (ISO 10140-2) and the rating standard (ISO 717-1)
- the exact configuration: glass type and thickness, profile, seals and whether a door was included
- the result: Rw, with C and Ctr where given
Line Systems walls are acoustically tested by official European laboratories. BSI states Rw for Line Systems partitions only per tested configuration, with the laboratory, report number and date, and sends the report for the build-up that matches your target. The systems are compared on the comparison page, and the frameless double-glazed option is described on the Glass Acoustic page.