Skip to content

Engineered demountable partitions vs tempered glass

Tempered glass is a safety glass, heat- or chemically treated so that it cannot be cut or drilled afterwards. A site-built partition uses tempered panes made to size and fixed on site. An engineered demountable partition is a tested system of profiles, glass, seals and doors that can be taken down and rebuilt when the layout changes.

Published by BSI on 31 October 2026

What tempered glass is

In Saudi offices, glass partitions are often described as سيكوريت, the local name for tempered (toughened) glass. US federal safety glazing rules define tempered glass as specially heat-treated or chemically treated glass that cannot be cut, drilled, ground or polished after treatment without breaking, and that, when highly tempered, breaks into small particles if fractured. Annealed glass, by contrast, is cooled slowly so it can still be cut. In the Gulf, GSO EN 12150-1 covers the tolerances, flatness, edgework, fragmentation and mechanical characteristics of thermally toughened safety glass for buildings.

That is a definition of a material and its safety behaviour. It says nothing about the partition built from it: how the joints and the door are sealed, what sound insulation the finished wall gives, or whether the wall can be changed later.

How a site-built glass partition comes together

A site-built partition starts with measurements on site. Because tempered glass cannot be cut after treatment, every pane is cut, edged and drilled to size before tempering, then fixed in channels or fittings, with the joints sealed and the doors hung on separate hardware. Each element is a separate decision, and the performance of the whole is known only if that exact build-up has been tested. A new layout generally means new panes, since a pane made for one opening cannot be trimmed for another.

What an engineered demountable system adds

  • Tested acoustics. Line Systems walls are acoustically tested by official European laboratories, and BSI states Rw only per tested configuration, with the laboratory, report number and date.
  • One family. Glass Acoustic (frameless double glazing with transparent PETG glass-to-glass joints, 10, 12 or 16 mm glass on a 100 × 36 mm profile), Glass Skin (double glazing bonded flush), Glass Slim (single glazing, also in a Slim Double configuration) and the solid PA 100 Opaque connect in one wall run with Line Systems doors.
  • Factory production. Components are produced in Sintra, Portugal, from the BIM model, and Line Systems holds ISO 9001 and ISO 14001.
  • Change without demolition. When the layout changes, the walls are taken down and rebuilt.
  • One accountable supplier. BSI represents Line Systems in the Kingdom, with specification support, shop drawings, supply, installation and after-sales from Riyadh.

Side by side

Site-built tempered glass and an engineered demountable system compared
AspectSite-built tempered glassEngineered demountable system
What you buyGlass panes and fittings, assembled on siteA wall system: profiles, glass, seals and doors
Acoustic evidenceOnly if that exact build-up has been testedRw per tested configuration, with the laboratory report
GlassPanes cut and drilled before tempering, each for one openingGlass specified within the system, e.g. 10, 12 or 16 mm for Glass Acoustic
DoorsSeparate hardware and supplyDoors from the same system family
Layout changeNew panes and fixings, as a ruleDemount and rebuild
ResponsibilityOften split between glass supplier, hardware supplier and installerOne supplier for walls, doors and glazing

Five checks before comparing quotes

  1. The acoustic test report for the exact build-up: laboratory, report number, date, glass, seals and door.
  2. The standard the glass complies with, such as GSO EN 12150-1 for toughened safety glass.
  3. Shop drawings for the junctions with the ceiling, floor and façade, and for the doors.
  4. What happens, and what it costs, when the layout changes.
  5. Who answers for the whole wall after handover.

The four Line Systems walls are described on the Line Systems page and compared on the comparison page.

Questions, answered.

Is tempered glass the same as a glass partition system?

No. Tempered glass is a type of safety glass: treated so that it cannot be cut or drilled afterwards, and, when highly tempered, breaking into small particles. A partition system is the whole wall: profiles, glass, seals, junctions and doors, tested together.

Can tempered glass be cut or drilled on site?

No. Tempered glass cannot be cut, drilled, ground or polished after treatment without breaking, so all cutting, edgework and holes are done before tempering. That is why site-built partitions depend on accurate site measurements, and why a changed layout usually needs new panes.

Why does an acoustic test report matter?

Sound insulation belongs to the tested build-up, not to the glass alone. A report names the laboratory, report number, date and configuration, so you can check that the wall being priced is the wall that was tested. BSI states Rw for Line Systems only per tested configuration and sends the matching report on request.

Keep reading.

  • Demountable partitions vs gypsum board

    A gypsum board partition is built on site in stages: framing, boards, taped joints and paint, and it is demolished when the layout changes. A demountable partition is made in a factory and assembled on site, so it can be taken down and rebuilt elsewhere. Line Systems PA 100 Opaque is designed as the modular alternative to gypsum walls.

  • What a partition's Rw rating means

    Rw, the weighted sound reduction index, is a single figure in decibels that rates how well a building element such as a wall, door or window stops airborne sound in a laboratory test. ISO 717-1 defines it from measurements made to ISO 10140-2. A higher Rw means better insulation, but it is not the performance of a finished room.

Apply it to your project.

Bring the drawings. BSI will turn the principle into a specification for your building.

Enquire Email